1WW COOLING SERVICE DATA
Condition |
Specified Condition |
|---|---|
Standard valve opening temperature |
100 °C (212 °F) |
Item |
Condition |
Specified Condition |
|---|---|---|
Cooling fan motor |
Battery voltage applied at 20°C (68°F) |
12.2 to 15.7 A |
No. 2 cooling fan motor |
Battery voltage applied at 20°C (68°F) |
11.7 to 15.2 A |
Item |
Condition |
Specified Condition |
|---|---|---|
Reserve tank cap |
Standard pressure (for brand-new reserve tank cap) |
93 to 123 kPa (0.9 to 1.3 kgf/cm2, 13.5 to 18.0 psi) |
Minimum pressure (for used reserve tank cap) |
79 kPa (0.8 kgf/cm2, 11.5 psi) |
Item |
Tester Connection |
Condition |
Specified Condition |
|---|---|---|---|
FAN NO. 1 relay |
3 - 5 |
Battery voltage not applied between terminals 1 and 2 |
10 kΩ or higher |
Battery voltage applied between terminals 1 and 2 |
Below 1 Ω |
||
FAN NO. 2 relay |
3 - 4 |
Battery voltage not applied between terminals 1 and 2 |
Below 1 Ω |
Battery voltage applied between terminals 1 and 2 |
10 kΩ or higher |
||
3 - 5 |
Battery voltage not applied between terminals 1 and 2 |
10 kΩ or higher |
|
Battery voltage applied between terminals 1 and 2 |
Below 1 Ω |
||
FAN NO. 3 relay |
3 - 5 |
Battery voltage not applied between terminals 1 and 2 |
10 kΩ or higher |
Battery voltage applied between terminals 1 and 2 |
Below 1 Ω |
Capacity |
Classification |
|---|---|
w/o Combustion Type Power Heater: 7.0 liters (7.4 US qts, 6.2 Imp. qts) |
Toyota recommends the use of approved "Toyota Premium Long Life Coolant for 1WW engines" or equivalent. |
w/ Combustion Type Power Heater: 7.3 liters (7.7 US qts, 6.4 Imp. qts) |