INTAKE AIR TEMPERATURE SENSOR INSPECTION

PROCEDURE

  1. INSPECT INLET AIR TEMPERATURE SENSOR

    1. Partially soak the inlet air temperature sensor in water and warm up the water.

      A294055C01

      *a

      Component without harness connected

      (Intake Air Temperature Sensor)

      *b

      Resistance kΩ

      *c

      Temperature °C (°F)

      *d

      Acceptable Range

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Temperature Condition

      Specified Condition

      1 - 2

      Approximately 20°C (68°F)

      2.21 to 2.65 kΩ

      Note:

      While checking the inlet air temperature sensor in water, be careful not to allow water to contact the terminals. After checking, wipe off any water on the inlet air temperature sensor.

      If the result is not as specified, replace the inlet air temperature sensor.