THEFT DETERRENT SYSTEM Security Horn Circuit
| DTC Code | DTC Name |
|---|---|
| Security Horn Circuit |
DESCRIPTION
When the theft deterrent system is switched from the armed state to the alarm sounding state, the main body ECU (multiplex network body ECU) transmits a signal to cause the security horn to sound at intervals of 0.4 seconds.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
PERFORM ACTIVE TEST USING GTS (SECURITY HORN)
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Main Body / Active Test.
Perform the Active Test according to the display on the GTS.
Body Electrical > Main Body > Active Test
Tester Display
Measurement Item
Control Range
Diagnostic Note
Security Horn
Security horn
OFF/ON
-
Body Electrical > Main Body > Active Test
Tester Display
Security Horn
OK
The security horn assembly sounds and stops correctly when operated through the GTS.
Result
Proceed to
OK
NG
INSPECT SECURITY HORN ASSEMBLY
Remove the security horn.
Check the operation of the security horn assembly.
OK
Battery Connection
Specified Condition
Battery positive (+) → Terminal 1
Battery negative (-) → Security horn body
Horn sounds
Result
Proceed to
OK
NG
INSPECT S-HORN RELAY
-
*1
S-HORN Relay
Remove the S-HORN relay from the No. 4 relay block.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 - 5
When battery voltage is not applied between terminals 1 and 2
10 kΩ or higher
3 - 5
When battery voltage is applied between terminals 1 and 2
Below 1 Ω
Result
Proceed to
OK
NG
NG REPLACE S-HORN RELAY
-
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
Remove the main body ECU (multiplex network body ECU).
*a
Component without harness connected
(Instrument Panel Junction Block Assembly)
-
-
Disconnect the 3C instrument panel junction block assembly connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3C-40 - MB-17 (SH)
Always
Below 1 Ω
Result
Proceed to
OK
NG
CHECK HARNESS AND CONNECTOR (BATTERY - S-HORN RELAY)
-
*1
No. 4 Relay Block
Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection
Condition
Specified Condition
No. 4 relay block S-HORN relay terminal 1 - Body ground
Always
11 to 14 V
No. 4 relay block S-HORN relay terminal 5 - Body ground
Always
11 to 14 V
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
-
CHECK HARNESS AND CONNECTOR (S-HORN RELAY - SECURITY HORN ASSEMBLY)
-
*1
No. 4 Relay Block
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
No. 4 relay block S-HORN relay terminal 3 - A122-1
Always
Below 1 Ω
No. 4 relay block S-HORN relay terminal 3 - Body ground
Always
10 kΩ or higher
A122-1 - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
-
CHECK HARNESS AND CONNECTOR (S-HORN RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
-
*1
No. 4 Relay Block
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
No. 4 relay block S-HORN relay terminal 2 - 3C-40
Always
Below 1 Ω
No. 4 relay block S-HORN relay terminal 2 - Body ground
Always
10 kΩ or higher
3C-40 - Body ground
Always
10 kΩ or higher
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR
-