THERMOSTAT INSTALLATION
PROCEDURE
INSTALL THERMOSTAT
Install a new gasket to the thermostat.
-
*a
Jiggle Valve
Install the thermostat with the jiggle valve facing upward.
Tip:The jiggle valve may be set within 10° on either side of the prescribed position.
INSTALL WATER INLET
Install the water inlet with the 3 bolts.
11 N*m
112 kgf*cm
8 ft.*lbf
INSTALL NO. 4 WATER BY-PASS PIPE
Apply soapy water to a new O-ring and install it to the No. 4 water by-pass pipe.
Install the No. 4 water by-pass pipe with the bolt.
11 N*m
112 kgf*cm
8 ft.*lbf
Connect the water by-pass hose and slide the clip to secure it.
CONNECT NO. 2 RADIATOR HOSE
Connect the No. 2 radiator hose and slide the clip to secure it.
ADD ENGINE COOLANT
INSPECT FOR COOLANT LEAK