VACUUM SWITCHING VALVE(for ACIS) INSPECTION
PROCEDURE
INSPECT VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
27 to 33 Ω
1 - Valve body
Always
10 kΩ or higher
2 - Valve body
If the result is not as specified, replace the vacuum switching valve assembly (for ACIS).
Check the vacuum switching valve assembly (for ACIS) operation.
-
*a
Filter
*b
Port E
*c
Air
When vacuum is applied to the port (E), check that air is sucked into the filter.
Standard
Air is sucked into the filter.
If the result is not as specified, replace the vacuum switching valve assembly (for ACIS).
-
*a
Air
*b
Port E
*c
Port F
Apply battery voltage across the terminals. When vacuum is applied to the port (F), check that air is sucked into the port (E).
Standard
Air is sucked into the port (E).
If the result is not as specified, replace the vacuum switching valve assembly (for ACIS).
-