BLOWER RESISTOR INSPECTION

PROCEDURE

  1. INSPECT BLOWER RESISTOR (for Manual Air Conditioning System)

    1. E145426C04

      *A

      for LHD

      *B

      for RHD

      *a

      Component without harness connected

      (Blower Resistor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      for LHD

      Tester Connection

      Condition

      Specified Condition

      4 (E) - 1 (HI)

      Always

      3.12 to 3.60 Ω

      2 (M1) - 1 (HI)

      Always

      1.45 to 1.67 Ω

      3 (M2) - 1 (HI)

      Always

      0.52 to 0.60

      Standard Resistance

      for RHD

      Tester Connection

      Condition

      Specified Condition

      1 (E) - 4 (HI)

      Always

      3.12 to 3.60 Ω

      3 (M1) - 4 (HI)

      Always

      1.45 to 1.67 Ω

      2 (M2) - 4 (HI)

      Always

      0.52 to 0.60

      • If the result is not as specified, replace the blower resistor.