MULTI-MODE MANUAL TRANSAXLE ECU(for RHD) REMOVAL

PROCEDURE

  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note:

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  2. REMOVE NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY (w/ Instrument Panel Under Cover)

  3. REMOVE GLOVE COMPARTMENT DOOR ASSEMBLY

  4. REMOVE TCM

    1. C274998

      Disconnect the 4 connectors from the TCM.

    2. C274999

      Remove the 2 bolts and TCM from the body.