CHARGING SYSTEM DATA LIST / ACTIVE TEST
DATA LIST
Tip:Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note:In the table below, the values listed under Normal Condition are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Warm up the engine.
Turn the ignition switch off.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Data List.
According to the display on the GTS, read the Data List.
Powertrain > Engine > Data List
Tester Display
Measurement Item
Range
Normal Condition
Diagnostic Note
Battery Voltage
Battery voltage
Min.: 0.0 V
Max.: 65.5 V
11 to 14 V (Idling)
If the result is not as specified, abnormal battery voltage is suspected.
Battery Sensor Voltage
Battery sensor voltage
Min.: 0.000 V
Max.: 79.998 V
11 to 14 V (Idling)
w/ Stop and Start System
Battery Current
Battery current
Min.: -125.0 A
Max.: 124.9 A
Changes according to alternator output
(While driving after engine warmed up)
If the result is not as specified, a malfunction of LIN communication is suspected.
w/ Stop and Start System
Battery Temperature
Battery temperature
Min.: -40.0°C (-40°F)
Max.: 6513.5 °C (11756 °F)
Changes according to actual temperature
(While driving after engine warmed up)
If the result is not as specified, a malfunction of LIN communication is suspected.
w/ Stop and Start System
Alternator Output Duty Ratio
Generator output duty
Min.: 0.0%
Max.: 399.9%
Changes in accordance with the generator output
If the result is not as specified, a malfunction of the charging control system is suspected.
Alternator Voltage - Non Active Test
Requested voltage when regulator forced drive is not executed
Min.: 0.000 V
Max.: 79.998 V
12.2 to 15.3 V
(After engine start (Varies with regulator temperature or driving conditions))
Active Test support data
Voltage of Alternator
Requested voltage when regulator forced drive is executed
Min.: 0.0 V
Max.: 79.9 V
Required instruction voltage value when the Active Test "Control the Voltage of Alternator" is executed (12.5 to 14.8 V): After engine started
Malfunction of the charging control system can be the cause of malfunction
Previous Trip Alternator Max Output Time
Generator maximum generating time during previous drive
Min.: 0 sec.
Max.: 65535 sec.
-
w/ Stop and Start System
Initial Engine Battery Minimum Voltage
Minimum battery voltage at engine start
Min.: 0.0 V
Max.: 25.5 V
-
w/ Stop and Start System
Previous Trip Charge Control Time
Charging control time during previous drive
Min.: 0 sec.
Max.: 65535 sec.
-
w/ Stop and Start System
Previous Trip Average Battery Temperature
Battery average temperature during previous drive
Min.: -40°C (-40°F)
Max.: 215°C (419°F)
-
w/ Stop and Start System
Tip:Normal Condition: If no idling conditions are specified, the shift lever should be in N (Neutral) or P, and the A/C switch and all accessory switches should be off.
ACTIVE TEST
Tip:Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Active Test.
According to the display on the GTS, perform the Active Test.
Powertrain > Engine > Active Test
Tester Display
Measurement Item
Control Range
Diagnostic Note
Control the Voltage of Alternator
Requested output voltage of generator regulator during forced activation
Between 12.5 and 14.8 V
Test is possible after engine start