DIFFERENTIAL PRESSURE SENSOR INSTALLATION

PROCEDURE

  1. INSTALL DIFFERENTIAL PRESSURE SENSOR ASSEMBLY

    1. A210654C01

      *1

      Vacuum Transmitting Hose Assembly

      *2

      No. 2 Vacuum Transmitting Hose Assembly

      *a

      Front of Vehicle

      *b

      Paint Mark (Yellow)

      *c

      Paint Mark (Red)

      *d

      LH Side

      *e

      Paint Mark

      Connect the vacuum transmitting hose assembly and No. 2 vacuum transmitting hose assembly and slide the 2 clips to secure them.

      Note:

      Connect the vacuum transmitting hose assembly and No. 2 vacuum transmitting hose assembly so that the paint marks of the vacuum transmitting hose assembly and No. 2 vacuum transmitting hose assembly are within the area shown in the illustration.

    2. A295022

      Install the differential pressure sensor assembly with the bolt.

      8.0 N*m

      82 kgf*cm

      71 in.*lbf

    3. Connect the differential pressure sensor connector and wire harness clamp.

  2. INSTALL COWL TOP VENTILATOR LOUVER SUB-ASSEMBLY