EGR BYPASS VALVE SWITCHING VALVE INSPECTION
PROCEDURE
INSPECT EGR BYPASS VALVE SWITCHING VALVE (NO. 1 VACUUM SWITCHING VALVE ASSEMBLY)
-
*a
Component without harness connected (EGR Bypass Valve Switching Valve (No. 1 Vacuum Switching Valve Assembly))
Inspect the EGR bypass valve switching valve (No. 1 vacuum switching valve assembly) resistance.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
33 to 39 Ω
If the result is not as specified, replace the EGR bypass valve switching valve (No. 1 vacuum switching valve assembly).
-
*a
Port E
*b
Port F
*c
Filter
*d
Air
Apply battery voltage between the terminals of the EGR bypass valve switching valve (No. 1 vacuum switching valve assembly) and check that the following occurs when blowing air to the port (E).
OK
Measurement Condition
Specified Condition
Battery voltage applied between terminals 1 and 2
Air flows from port (F)
Battery voltage not applied between terminals 1 and 2
Air flows from filter