THERMOSTAT INSPECTION
PROCEDURE
INSPECT WATER INLET
Check the valve opening temperature of the thermostat (element, spring and frame).
Standard Valve Opening Temperature
80 to 84°C (176 to 183°F)
Tip:If the valve opening temperature is not as specified, replace the thermostat (element, spring and frame).
-
*a
8.5 mm or more
Check the valve lift.
Standard Valve Lift
8.5 mm (0.335 in.) or more at 95°C (203°F)
Tip:If the valve lift is not as specified, replace the thermostat (element, spring and frame).
Check that the valve is fully closed when the element is at low temperatures (below 77°C (171°F)).
Tip:If the valve is not fully closed, replace the thermostat (element, spring and frame).