AIR CONDITIONING SYSTEM


  1. CONSTRUCTION


    1. An air conditioning unit that is compatible with left and right independent temperature control is used.*

      *: Models with automatic air conditioning system

    2. An inside-and-outside dual air layer type air conditioning unit is used. This type of air conditioning unit introduces outside air to the upper side and circulates inside air to the lower side, thus achieving anti-fogging performance and ventilation loss reduction.*

      *: Models with dual air layer type air conditioning unit

    3. A Straight Flow Aluminum-II (SFA-II) heater core that is compact and offers advanced performance is used.

    4. A compact wide-angle high flow defroster that gives the defroster nozzle assembly inner wall a radial shape is used to ensure superior defroster performance.

    5. A pollen removal type clean air filter is provided.

      Figure 1. Air Conditioning Unit Layout Parts Location

      A001N0WC01
      *1 Air Conditioning Unit Assembly - -
      *a The illustrations shown are example only. - -

      Figure 2. Duct Layout Parts Location

      A001MYVC01
      *A Models with Dual Air Layer Type Air Conditioning Unit for LHD - -
      *1 Center Register Duct *2 Side Register Duct LH
      *3 Side Register Duct RH *4 Front Footwell Register Duct LH
      *5 Front Footwell Register Duct RH *6 Rear Footwell Register Duct LH
      *7 Rear Footwell Register Duct RH *8 Front Defroster Duct
      *9 Side Defroster Duct LH *10 Side Defroster Duct RH
      *a The illustrations shown are example only. - -
  2. OPERATION


    1. Mode Position and Damper Operation

      Figure 3. Models with Dual Air Layer Type Air Conditioning Unit and Automatic Air Conditioning System

      A001MH7C04
      *A Models with PTC Heater *B LHD Models
      *1 Air Mix Control Damper (Driver Side) *2 Air Mix Control Damper (Front Passenger Side)
      *3 Side Defroster LH *4 Front Defroster
      *5 Side Defroster RH *6 Air Inlet Control Damper (Lower Side)
      *7 Air Inlet Control Damper (Upper Side) *8 Clean Air Filter
      *9 Blower Motor with Fan Sub-assembly *10 No. 1 Cooler Evaporator Sub-assembly
      *11 Air Mix Control Damper *12 Heater Radiator Unit Sub-assembly
      *13 PTC Heater (Quick Heater Assembly) *14 Mode Switching Damper
      *15 Front Footwell Register LH *16 Front Footwell Register RH
      *17 Side Register LH *18 Center Register
      *19 Side Register RH *20 Rear Footwell Register LH
      *21 Rear Footwell Register RH - -
      *a Illustration Image View from [A] *b [A] View
      *c Recirculated Air *d Fresh Air
      Functions of Main Dampers
      Control Damper Operation Position Damper Position Operation
      Air Inlet Control Damper FRESH A1, B1 Allows fresh air to enter.
      RECIRCULATION A2, B2 Causes internal air to recirculate.
      Air Mix Control Damper HI - LO C1 - C2 Varies the driver side mixture ratio of cool air and hot air in order to regulate the temperature continuously from HI to LO.
      D2 - D1 Varies the front passenger side mixture ratio of cool air and hot air in order to regulate the temperature continuously from HI to LO.
      Air Outlet Control Damper

      DEF

      A001N2B
      F, H, K Defrosts the windshield through the center defroster, side defrosters and side registers.

      FOOT/DEF

      A001MSX
      F, H, J to K Defrosts the windshield through the center defroster, side defrosters and side registers, while air is also blown out from the front footwell registers and rear footwell register*.

      FOOT

      A001MVO
      E, (E to F), H, J Air blows out of the front footwell registers, rear footwell registers* and side registers. In addition, air blows out slightly from the center defroster and side defrosters.

      B/L

      A001N0U
      E, G to I, J to K Air blows out of the center registers, side registers, front footwell registers and rear footwell registers*.

      FACE

      A001MLV
      E, G, K Air blows out of the center registers and side registers.

      *: LHD Models

      Figure 4. Models with Single Air Layer Type Air Conditioning Unit and Automatic Air Conditioning System

      A001MX7C02
      *1 Air Mix Control Damper (Driver Side) *2 Air Mix Control Damper (Front Passenger Side)
      *3 Side Defroster LH *4 Front Defroster
      *5 Side Defroster RH *6 Air Inlet Control Damper
      *7 Clean Air Filter *8 Blower Motor with Fan Sub-assembly
      *9 No. 1 Cooler Evaporator Sub-assembly *10 Air Mix Control Damper
      *11 Heater Radiator Unit Sub-assembly *12 Mode Switching Damper
      *13 Front Footwell Register LH *14 Front Footwell Register RH
      *15 Side Register LH *16 Center Register
      *17 Side Register RH - -
      *a Illustration Image View from [A] *b [A] View
      *c Recirculated Air *d Fresh Air
      Functions of Main Dampers
      Control Damper Operation Position Damper Position Operation
      Air Inlet Control Damper FRESH A1 Allows fresh air to enter.
      RECIRCULATION A2 Causes internal air to recirculate.
      Air Mix Control Damper HI - LO B1 - B2 Varies the driver side mixture ratio of cool air and hot air in order to regulate the temperature continuously from HI to LO.
      C2 - C1 Varies the front passenger side mixture ratio of cool air and hot air in order to regulate the temperature continuously from HI to LO.
      Air Outlet Control Damper

      DEF

      A001N2B
      E, G, J Defrosts the windshield through the center defroster, side defrosters and side registers.

      FOOT/DEF

      A001MSX
      E, G, I to J Defrosts the windshield through the center defroster, side defrosters and side registers, while air is also blown out from the front footwell registers.

      FOOT

      A001MVO
      D, (D to E), G, I Air blows out of the front footwell registers and side registers. In addition, air blows out slightly from the center defroster and side defrosters.

      B/L

      A001N0U
      D, F to H, I to J Air blows out of the center registers, side registers and front footwell registers.

      FACE

      A001MLV
      D, F, J Air blows out of the center registers and side registers.

      Figure 5. Models with Dual Air Layer Type Air Conditioning Unit and Manual Air Conditioning System

      A001MUAC01
      *1 Air Mix Control Damper *2 Side Defroster LH
      *3 Front Defroster *4 Side Defroster RH
      *5 Air Inlet Control Damper (Lower Side) *6 Air Inlet Control Damper (Upper Side)
      *7 Clean Air Filter *8 Blower Motor with Fan Sub-assembly
      *9 No. 1 Cooler Evaporator Sub-assembly *10 Heater Radiator Unit Sub-assembly
      *11 PTC Heater (Quick Heater Assembly) *12 Mode Switching Damper
      *13 Front Footwell Register LH *14 Front Footwell Register RH
      *15 Side Register LH *16 Center Register
      *17 Side Register RH *18 Rear Footwell Register LH
      *19 Rear Footwell Register RH - -
      *a Recirculated Air *b Fresh Air
      Functions of Main Dampers
      Control Damper Operation Position Damper Position Operation
      Air Inlet Control Damper FRESH A1, B1 Allows fresh air to enter.
      RECIRCULATION A2, B2 Causes internal air to recirculate.
      Air Mix Control Damper HI - LO D - C Varies the mixture ratio of cool air and hot air in order to regulate the temperature continuously from HI to LO.
      Air Outlet Control Damper

      DEF

      A001N2B
      F, H, K Defrosts the windshield through the center defroster, side defrosters and side registers.

      FOOT/DEF

      A001MSX
      F, H, J to K Defrosts the windshield through the center defroster, side defrosters and side registers, while air is also blown out from the front footwell registers and rear footwell registers.

      FOOT

      A001MVO
      E, (E to F), H, J Air blows out of the front footwell registers and rear footwell registers and side registers. In addition, air blows out slightly from the center defroster and side defrosters.

      B/L

      A001N0U
      E, G to I, J to K Air blows out of the center registers, side registers, front footwell registers and rear footwell registers.

      FACE

      A001MLV
      E, G, K Air blows out of the center registers and side registers.

      Figure 6. Models with Single Air Layer Type Air Conditioning Unit and Except Automatic Air Conditioning System

      A001MPWC01
      *A Models with Manual Air Conditioning System - -
      *1 Air Mix Control Damper *2 Side Defroster LH
      *3 Front Defroster *4 Side Defroster RH
      *5 Air Inlet Control Damper *6 Clean Air Filter
      *7 Blower Motor with Fan Sub-assembly *8 No. 1 Cooler Evaporator Sub-assembly
      *9 Heater Radiator Unit Sub-assembly *10 Mode Switching Damper
      *11 Front Footwell Register LH *12 Front Footwell Register RH
      *13 Side Register LH *14 Center Register
      *15 Side Register RH - -
      *a Recirculated Air *b Fresh Air
      Functions of Main Dampers
      Control Damper Operation Position Damper Position Operation
      Air Inlet Control Damper FRESH A1 Allows fresh air to enter.
      RECIRCULATION A2 Causes internal air to recirculate.
      Air Mix Control Damper HI - LO C - B Varies the mixture ratio of cool air and hot air in order to regulate the temperature continuously from HI to LO.
      Air Outlet Control Damper

      DEF

      A001N2B
      E, G, J Defrosts the windshield through the center defroster, side defrosters and side registers.

      FOOT/DEF

      A001MSX
      E, G, I to J Defrosts the windshield through the center defroster, side defrosters and side registers, while air is also blown out from the front footwell registers.

      FOOT

      A001MVO
      D, (D to E), G, I Air blows out of the front footwell registers and side registers. In addition, air blows out slightly from the center defroster and side defrosters.

      B/L

      A001N0U
      D, F to H, I to J Air blows out of the center registers, side registers and front footwell registers.

      FACE

      A001MLV
      D, F, J Air blows out of the center registers and side registers.
    2. Air Outlets and Airflow Volume

      A001N9U
      Mode FACE FOOT DEF
      Center Side Front Rear* Center Side
      A B C D E F

      FACE

      A001MLV
      A001MLU A001MLU A001N88 A001N88 A001N88 A001N88

      B/L

      A001N0U
      A001N30 A001N30 A001N30 A001N30 A001N88 A001N59

      FOOT

      A001MVO
      A001N88 A001N59 A001N30 A001N30 A001N59 A001N59

      FOOT/DEF

      A001MSX
      A001N88 A001N59 A001N30 A001N30 A001N30 A001N59

      DEF

      A001N2B
      A001N88 A001N30 A001N88 A001N88 A001N30 A001N30

      *: Models with dual air layer type air conditioning unit for LHD

      Tech Tips

      The size of the circle ○ indicates the proportion of airflow volume.