WHEN REMOVING,INSTALLING,REPAIRING OR REPLACING PARTS PROCEDURES NECESSARY WHEN BATTERY TERMINAL IS DISCONNECTED / RECONNECTED

Refer to the LEXUS Repair Manual for each work procedure.


  1. PROCEDURES NECESSARY WHEN CABLE IS DISCONNECTED/RECONNECTED TO BATTERY

    Procedures Necessary when Cable is Disconnected/Reconnected to Battery Terminal
    Necessary Procedure Effect or Inoperative Function when Necessary Procedure is not Performed
    Initialization of steering angle sensor VGRS system function
    Correction of steering angle neutral point Multi-terrain monitor system function
    Reset back door close position Power back door system

    Note

    After the engine switch is turned off, the multi-media module receiver assembly records various types of memory and settings. As a result, after turning the engine switch off, be sure to wait for the time specified in the following table before disconnecting the cable from the negative (-) battery terminal.

    Waiting Time before Disconnecting Cable from Negative (-) Battery Terminal
    Condition Waiting Time
    Vehicle enrolled in telematics system 6 minutes
    Vehicle not enrolled in telematics system 1 minute