TILT UP CAB
CAUTION:
Make sure that the vehicle is on a level surface before tilting the cab up.
Make sure that all the doors are closed before tilting the cab up.
Make sure that nobody is inside or near the cab when tilting it up.
Be sure to have 2 people tilt the cab up when a heavy object such as a roof rack or cargo carrier is installed to the cab.
Be sure to remove anything set on top of the cab before tilting it up.
Make sure that the cab is securely locked in place after it is tilted up.
Make sure that there are no tools, cloths, etc. left in the engine room before tilting the cab back down.
Make sure that the cab is securely locked in place after tilting it back down.
REMOVE INJECTOR ASSEMBLY
CHECK VALVE CLEARANCE
| *1 | Timing Mark |
Set the No. 1 cylinder to TDC/compression.
Tech Tips
Make sure that there is free play in the No. 1 cylinder rocker arms and that there is no free play in the No. 4 cylinder rocker arms.
If not, turn the crankshaft 1 revolution (360°) to set the No. 1 cylinder to TDC/compression.
| *1 | No. 1 Cylinder Intake Valve |
| *2 | No. 3 Cylinder Exhaust Valve |
Check the valve clearance of the No. 1 cylinder intake valve and No. 3 cylinder exhaust valve.
| Standard Valve Clearance (Cold) | ||||||
|---|---|---|---|---|---|---|
|
Note
Do not apply excessive force to the valve adjusting screw.
Tech Tips
If the clearance is not as specified, record the measured value, and then adjust the valve clearance.
| *1 | No. 1 Cylinder Exhaust Valve |
| *2 | No. 2 Cylinder Intake Valve |
Check the valve clearance of the No. 1 cylinder exhaust valve and No. 2 cylinder intake valve.
| Standard Valve Clearance (Cold) | ||||||
|---|---|---|---|---|---|---|
|
Note
Do not apply excessive force to the valve adjusting screw.
Tech Tips
If the clearance is not as specified, record the measured value, and then adjust the valve clearance.
| *1 | Timing Mark |
Turn the crankshaft 1 revolution (360°) clockwise to set the No. 4 cylinder to TDC/compression.
Tech Tips
Make sure that there is free play in the No. 4 cylinder rocker arms and that there is no free play in the No. 1 cylinder rocker arms.
If not, turn the crankshaft 1 revolution (360°) to set the No. 4 cylinder to TDC/compression.
| *1 | No. 2 Cylinder Exhaust Valve |
| *2 | No. 4 Cylinder Intake Valve |
Check the valve clearance of the No. 2 cylinder exhaust valve and No. 4 cylinder intake valve.
| Standard Valve Clearance (Cold) | ||||||
|---|---|---|---|---|---|---|
|
Note
Do not apply excessive force to the valve adjusting screw.
Tech Tips
If the clearance is not as specified, record the measured value, and then adjust the valve clearance.
| *1 | No. 3 Cylinder Intake Valve |
| *2 | No. 4 Cylinder Exhaust Valve |
Check the valve clearance of the No. 3 cylinder intake valve and No. 4 cylinder exhaust valve.
| Standard Valve Clearance (Cold) | ||||||
|---|---|---|---|---|---|---|
|
Note
Do not apply excessive force to the valve adjusting screw.
Tech Tips
If the clearance is not as specified, record the measured value, and then adjust the valve clearance.
ADJUST VALVE CLEARANCE
| *a | TDC of No. 1 and No. 4 Cylinder |
| *b | TDC of No. 2 and No. 3 Cylinder |
| *c | Timing Mark |
Turn the crankshaft clockwise to align the timing mark on the crankshaft pulley with the pointer on the timing gear case.
| *1 | Adjusting Screw |
| *2 | Feeler Gauge |
| *3 | Lock Nut |
With each piston positioned at TDC on the compression stroke, using a feeler gauge, adjust each valve clearance.
| Standard Valve Clearance (Cold) | ||||||
|---|---|---|---|---|---|---|
|
Tech Tips
The feeler gauge should move with a very slight pull.
Loosen the lock nut on the valve rocker arm and loosen the adjusting screw.
Insert a 0.30 mm (0.0118 in.) feeler gauge for the intake valve or a 0.45 mm (0.0177 in.) feeler gauge for the exhaust valve between the adjusting screw on the valve rocker arm and the valve bridge.
Turn the adjusting screw on the valve rocker arm until the feeler gauge slides with a very slight drag, and lock the adjusting screw with the lock nut.
INSTALL INJECTOR ASSEMBLY
BLEED AIR FROM FUEL SYSTEM
Loosen the bleeder plug.
|
Bleeder Plug |
Note
Make sure that the drain plug and bleeder plug of the filter on the fuel tank side are closed.
Bleed air using the priming pump on the fuel tank side.
Note
Place a container, etc. underneath the fuel filter to prevent fuel from spraying.
The hand pump must be pushed with a full stroke during pumping.
The maximum hand pump pumping speed is 2 strokes per second.
When the fuel pressure at the supply pump inlet port reaches a saturated pressure, the hand pump resistance increases.
If pumping is interrupted during the air bleeding process, fuel in the fuel line may return to the fuel tank. Continue pumping until the hand pump resistance increases.
If the hand pump resistance does not increase despite consecutively pumping 200 times or more, there may be a fuel leak between the fuel tank and fuel filter, the hand pump may be malfunctioning, or the vehicle may have run out of fuel.
If air bleeding using the hand pump is incomplete, the common rail pressure does not rise to the pressure range necessary for normal use and the engine cannot be started.
Tighten the bleeder plug.
Check if the engine starts.
Note
Even if air bleeding using the hand pump has been completed, the starter may need to be cranked for 10 seconds or more to start the engine.
Do not crank the engine continuously for more than 20 seconds. The battery may be discharged.
Use a fully-charged battery.
When the engine can be started, proceed to the next step.
Tech Tips
If the engine cannot be started, bleed air again using the hand pump until the hand pump resistance increases (refer to the procedures above). Then start the engine.
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the intelligent tester on.
Clear the DTCs Click here.
Start the engine.*1
| *a | Reference (Active Test operation) |
Enter the following menus: Powertrain / Engine and ECT / Active Test / Test the Fuel Leak.*2
Perform the following test 5 times with on/off intervals of 10 seconds: Active Test / Test the Fuel Leak.*3
| *a | Active Test operation | *b | Time |
| *c | ON | *d | OFF |
| *e | 1st time | *f | 2nd time |
| *g | 5th time | *h | 10 seconds |
| *i | 3 minutes or more | - | - |
Allow the engine to idle for 3 minutes or more after performing the Active Test for the 5th time.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Read Current DTCs.
If no DTCs are output, air bleeding is completed.
If DTCs are output, perform the following procedure.
Clear the DTCs Click here.
Repeat steps *1 to *3.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Read Current DTCs.
| OK |
|---|
| No DTCs are output |
INSPECT FOR FUEL LEAK
Perform the Active Test.
Replace the normal DLC3 cable (12 V specification) for the intelligent tester with the 24 V DLC3 cable.
Note
Be sure to use the 24 V DLC3 cable when connecting the intelligent tester to the DLC3. Using the normal DLC3 cable (12 V specification) will cause damage to the tester.
Connect the intelligent tester to the DLC3.
Start the engine.
Turn the intelligent tester on.
Enter the following menus: Powertrain / Engine and ECT / Active Test.
Perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Test the Fuel Leak | Pressurizes common rail interior and checks for fuel leaks | Stop or Start |
|
Check for leaks from the fuel system while performing the Active Test (with a fuel pressure applied).