ECD SYSTEM, Diagnostic DTC:P0045

DTC Code DTC Name
P0045 Turbocharger / Supercharger Boost Control Solenoid Circuit / Open

DESCRIPTION

The turbocharger system is comprised of the Variable Nozzle (VN) type turbocharger, the turbo motor driver and ECM.

The turbocharger sub-assembly has nozzle vanes which open and close to control the volume of the exhaust gas flowing into the turbine. This, in turn, controls the boost pressure. When the nozzle vanes move toward the closing direction, the pressure increases. When the vanes move toward the opening direction, the pressure decreases.

The turbocharger actuator mounted on the turbine side activates the nozzle vanes. The nozzle vane position sensor mounted on the actuator detects the opening angle of the nozzle vanes. The nozzle vane position sensor signal is sent via the turbo motor driver to the ECM. Then, based on the signal, the ECM actuates the actuator.

The ECM sends a target nozzle vane position signal to the turbo motor driver to obtain the nozzle vane position for the optimal boost pressure in accordance with the driving conditions.

P0045
DTC Detection Drive Pattern DTC Detection Condition Trouble Area
Warm up the engine and idle it for 1 second or more. Send trouble signal in VN turbo controller for 1 second or more (1 trip detection logic).
  • Open or short in VN turbo actuator circuit

  • Turbocharger sub-assembly

  • Turbocharger actuator (built into turbocharger sub-assembly)

  • ECM

WIRING DIAGRAM

A01CHVSE03

INSPECTION PROCEDURE

Note


  • After replacing the ECM, the new ECM needs registration Click here and initialization Click here.

  • Inspect the fuses for circuits related to this system before performing the following inspection procedure.

Tech Tips

Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was moving or stationary, whether the engine was warmed up or not, as well as other data recorded at the time of a malfunction.

PROCEDURE


  1. CHECK TURBOCHARGER SUB-ASSEMBLY (POWER SOURCE)


    1. A01CIWAE04
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Turbocharger Actuator)

      Disconnect the turbocharger actuator connector.

    2. Turn the ignition switch to ON.

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      T13-1 (+B) - T13-2 (GND) Ignition switch ON 18 to 27 V

    NG
    OK
  2. INSPECT TURBOCHARGER SUB-ASSEMBLY


    1. Inspect the turbocharger sub-assembly Click here.


    NG
    OK
  3. REPLACE ECM


    1. Replace the ECM Click here.


    NEXT
  4. CHECK WHETHER DTC OUTPUT RECURS


    1. Replace the normal DLC3 cable (12 V specification) for the intelligent tester with the 24 V DLC3 cable.

      Note

      Be sure to use the 24 V DLC3 cable when connecting the intelligent tester to the DLC3. Using the normal DLC3 cable (12 V specification) will cause damage to the tester.

    2. Connect the intelligent tester to the DLC3.

    3. Turn the ignition switch to ON.

    4. Turn the tester on.

    5. Enter the following menus: Powertrain / Engine and ECT / DTC.

    6. Read the DTCs.

      Result
      Result Proceed to
      DTC is not output A
      DTC P0045 is output B

    B
    A
  5. CHECK HARNESS OR CONNECTOR (TURBOCHARGER ACTUATOR - BODY GROUND)


    1. Disconnect the turbocharger actuator connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      T13-2 (GND) - Body ground Always Below 1 Ω
    3. Reconnect the turbocharger actuator connector.


    NG
    OK
  6. CHECK HARNESS OR CONNECTOR (TURBOCHARGER ACTUATOR - ENG ACT RELAY)


    1. Disconnect the turbocharger actuator connector.

    2. Remove the ENG ACT relay from the engine room relay block and junction block.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      T13-1 (+B) - ENG ACT relay terminal 5 Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      T13-1 (+B) or ENG ACT relay terminal 5 - Body ground Always 10 kΩ or higher
    4. Reconnect the turbocharger actuator connector.

    5. Reinstall the ENG ACT relay.


    NG
    OK