CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM(for 8NR-FTS), Diagnostic DTC:P074011 and P074015
| DTC Code | DTC Name |
|---|---|
| P074011 | Torque Converter Clutch Circuit Short to Ground |
| P074015 | Torque Converter Clutch Circuit Short to Battery or Open |
DESCRIPTION
Based on the signal received by the shift solenoid valve SL, the ECM uses the shift solenoid valve SLU to control the lock-up clutch pressure.
If there is an open or short in the shift solenoid valve SL circuit, the ECM stops sending current to the malfunctioning shift solenoid valve.
DTC No. |
Detection Item |
DTC Detection Condition |
Trouble Area |
MIL |
Memory |
Note |
|---|---|---|---|---|---|---|
P074011 |
Torque Converter Clutch Circuit Short to Ground |
1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
|
|
Comes on |
DTC stored |
SAE Code: P2769 |
P074015 |
Torque Converter Clutch Circuit Short to Battery or Open |
1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
|
|
Comes on |
DTC stored |
SAE Code: P2770 |
MONITOR DESCRIPTION
These DTCs indicate an open or short in the shift solenoid valve SL circuit. If there is an open or short in the shift solenoid valve SL circuit, the ECM detects the malfunction, illuminates the MIL and stores a DTC.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Drive the vehicle and confirm the lock-up on and off conditions according to Road Test.
Check for DTCs again.
PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)
-
*a
Component without harness connected
(Transmission Wire)
Disconnect the B185 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
3 (SL) - Body ground
20°C (68°F)
11 to 15 Ω
Connect the B185 transmission wire connector.
Result
Proceed to
OK
NG
NG REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLYClick here
-
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
Disconnect the B208 ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection
Condition
Specified Condition
B208-75 (SL) - Body ground
20°C (68°F)
11 to 15 Ω
Connect the B208 ECM connector.
Result
Proceed to
OK
NG
NG REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM)
REPLACE ECM
Replace the ECM.
Result
Proceed to
NEXT
REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
Replace the continuously variable transaxle assembly.
Result
Proceed to
NEXT