MANIFOLD ABSOLUTE PRESSURE SENSOR INSPECTION

PROCEDURE

  1. INSPECT NO. 2 TURBO PRESSURE SENSOR

    1. A327353C04

      *a

      Component without harness connected

      (No. 2 Turbo Pressure Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection

      Condition

      Specified Condition

      4 (THIM) - 2 (E2)

      -20°C (-4°F)

      13.8 to 18.6 kΩ

      20°C (68°F)

      2.09 to 2.81 kΩ

      80°C (176°F)

      0.274 to 0.370 kΩ

      If the result is not as specified, replace the No. 2 turbo pressure sensor.